Visit HYTEK Online Store
HYTEK Automation, Inc.
Home
Company
Products
Downloads
Consulting
Services
Contact Us
News
Recruitment
How To Buy
Customers
USB Data Acquisition
Web services for USB DAQ
iUSBDAQ - U120816
iUSBDAQ - U1208LOG
iUSBDAQ API
iDAQTest&Log
iUSBDAQ - U120816AO
Logger Data Conversion
iUSBDAQ - U1208DIV
iUSBDAQ - U1208AMP
LabVIEW Toolkits
PTPCam LabVIEW Toolkit
IVISION LabVIEW Toolkit
Nikon D1 LabVIEW Toolkit
Nikon Dx LabVIEW Toolkit
Stereo 3D Camera
3D Camera Driver
HYTEK 3D iVCam2.0
USB2.0 PC Camera
Signal Conditioning
Voltage Divider DIV4
Voltage Divider DIV8
Amplifier AMP1
Amplifier AMP8
Force Plate Systems
Force Plate System
Accessories
5V USB Power Adaptor
USB Cable
5V USB Lithium Battery Pack
USB2.0 Hub
Sensors
HY1-LP
pt100 Temperature Sensor
Amplifier AMP8
(
In Stock
)
$118USD
8 channels instrumentation amplifier. Can be used as signal conditioning for bridge sensors such as load cell, pressure
sensor and thermocouple sensor. 30% off if buy with iUSBDAQ data acquisition module.
AMP8 has 8 channel amplifiers with isolated outputs. It has 7 gain levels for selection,
showed as below:
6, 11, 51, 101, 201.4, 501, 1001
Please specify the gain values when purchasing, each channel can have different gain.
The default out of factory gain will be 201.4 if no specification from customer.
There is a switch on board for selecting the reference voltage. As show at below image
If this switch is at VREF position, it can shift amplified voltage to
higher level, that is the final output voltage will be Vin*G+1.65V. This is suitable for bipolar
signal, it shifts negative voltage to higher than 0V. This range voltage can then be
measured by iUSBDAQ data acquisition modules. If the input signal is unipolar signal, the
reference switch should be at GND, the relationship between input voltage and gain level
is: Vin*G<4.096V
If input voltage is bipolar, switch the reference to VREF, the relationship between input
voltage and gain level is:
2.446V>Vin*G>-1.65V
Connections:The outputs of the amplifiers can plug directly into iUSBDAQ USB data acquisition modules' pin1 - pin13. The amplifier's
output side pin order is: +5V, GND, AI0, AI1, AGND, AI2, AI3, AGND, AI4, AI5, AGND, AI6, AI7.
Input side: connecting the bridge type sensors such as load cell. Every 4 pins are a group, each group has pins 3.3V,V+,V-,GND.
3.3V is a reference voltage. Can be used as power supply to sensors.
Below diagram shows how to connect bridge type sensor to AMP:
Below diagram shows how to connect thermocouple to AMP:
AMP8 Image:
The output pins can changed to screw terminals if requested. Please specify when purchasing.
Save 30% if purchasing with our iUSBDAQs. Check out this bundle
iUSBDAQ - U1208AMP
.
Related Products:
iUSBDAQ - U120816
Lowest cost USB data acquisition module with 8 c...
$89USD
iUSBDAQ - U1208LOG
The unique 3-in-1 USB data acquisition module wi...
$199USD
iUSBDAQ - U120816AO
Low cost USB data acquisition module with 8 chan...
$89USD
iUSBDAQ - U1208AMP
USB DAQ with 8 channel instrumentation amplifier...
$171USD
©Copyright 2009 HYTEK Automation, Inc. All rights reserved.